UpstreamDownstreamMembrane
UltraGuard™ PVDF hollow-fiber UF systems provide an absolute barrier to turbidity, bacteria, and colloids. Compact skid design makes them ideal for both permanent facilities and temporary well-site RO pre-treatment.
Outside-in flow with reverse-pulse backwash and chemically enhanced backwash (CEB) sequencing maintains stable trans-membrane pressure even on dirty feeds. Integrity testing (PDT) is automated on a programmable interval.
Standard modules use 0.02 µm absolute PVDF fiber with high break-strength and chlorine tolerance up to 200 mg/L for sanitation cycles.
Process Schematic
WFS-UF-700
Full Specifications
- Pore Size
- 0.02 µm (absolute)
- Flow Range
- 25–3,000 GPM
- SDI Outlet
- <3 consistently
- Turbidity Outlet
- <0.1 NTU
- Membrane Material
- PVDF hollow fiber
- Flow Configuration
- Outside-in
- Backwash
- Reverse pulse + CEB
- Integrity Test
- Pressure decay (PDT) automated
- Chlorine Tolerance
- Up to 200 mg/L (CIP)
- Operating Pressure
- <30 PSI typical
- Recovery
- >95%
- Module Life
- 5–7 years typical
Configure your UltraGuard™ Ultrafiltration Skid